Subject: Bridgeport Series I & II stepper wiring For the Sigma motors: (identified by 8 terminals in pairs with a plastic partition between the terminals of each pair) To connect the phase windings in series and set the controller to 7 amps ( GECKO wiring recommended for orig BP type steppers*********) terminals: 6 jumpered to 5 3 connected to phase A+ 1 connected to phase A- 8 jumpered to 7 4 connected to phase B+ 2 connected to phase B- To connect the phase windings in parallel and set the controller to 7 amps terminals: 6 & 3 connected to phase A+ 1 & 5 connected to phase A- 4 & 8 connected to phase B+ 2 & 7 connected to phase B- ================================================================================= For the Superior motors: (identified by 8 terminals in a round pattern with no plastic partitions) To connect the phase windings in parallel and set the controller to 7-10 amps terminals: 6 & 3 connected to phase A+ 2 & 1 connected to phase A- 4 & 7 connected to phase B+ 5 & 8 connected to phase B-